Laboratory Services

Digoxin

Print this page

Updated Test Information:

Test Description
Digoxin
Synonym(s)

Lanoxin®

Test ID
DIG
Performing Lab

Incyte Diagnostics

General Information

A specimen should be collected at least 6 to 8 hours after drug administration. By this time, serum digoxin levels are expected to be in equilibrium with tissue levels and should correlate with pharmacologic effects.

Container Type

Red Top

Specimen Type

Serum

Specimen Requirements

Red Top
Aliquot Tube

Alternate Specimen Type

SST, Li-heparin, K2 EDTA and K3 EDTA plasma

Specimen Collection / Processing Instructions

Centrifuge and aliquot serum/plasma within 2 hours of collection

Minimum Sample Volume

1 mL

Pediatric Min. Volume (if applicable)

500 uL

Stability

7 days at 15-25 C, 14 days 2-8 C and 6 months at -20 C

Methodology

Homogeneous enzyme immunoassay

Estimated TAT

0-2 days

Testing Schedule

Monday-Saturday

CPT Code(s)

80162

Reference Range

0.5-1.0 ng/mL

LOINC Code(s)

10535-3